Take the file uBrowser. You want that your web project is displayed directly on the display by starting the Micro Browser App for Windows and you do not need the configuration page for different stations. There is also a possibility to start the project directly in the Autostart on Windows startup.
Firstly create a new Text document. In my example I named it start. Afterwards put the following text in the file:. The green part is the path where the Micro Browser application is stored. The blue part is the web project which you want to start IP Address with html file. Save the file. Rename the file from start.
If you want to start the application directly on windows startup, put this file in the folder Autostart. You do not have the option to display the web project in Full screen mode. It is an older software version which can be operated only on certain now no longer commercially available products. English German.
Installation and licensing The installation and licensing is very simple and can be done by the user independently.
Version history Version Remarks Note that the choice of the router or the DynDNS service from this document is sheer coincicence and does not mean that only this router works with PCD systems. For support request regarding the router functionality or DynDNS please contact the according provider.
This task can be done by the tool "nslookup" which is installed on every Windows system: Open the DOS console from the "Windows Start menu" select "Run Register Values. Criterias to choose an ADSL Router you need to know whether an analogue or ISDN version is required depends on the telephone line it must support "nailed up connections", which means that if the internet connection is not closed periodically and if for some reason the connection gets lost anyway, the Router re-establishes the connection it should contain a firewall it should support address translation, so you can route telegrams to port 80 to the PC with WebConnect and telegrams to port to a PCD directly.
Other ports should be blocked inwards an integrated switch is quite useful Zyxel Prestige ME-I does not support nailed up connections, so you need to run a software on the frontend PC which simulates Web traffic for instance come.
Without such a tool the Router closes the Internet connection after a while and you cannot access the frontend PC or PCD anymore until you create Web traffic on the PC user friendly configuration tool Zyxel Prestige H-I nice product with rich features, 4 Port Switch, supports nailed up connections.
Since we cut the supply of the unit for a moment at noon, the product works fine With the Webserver we use the product the other way around, which can cause problems with some products do not expect to get useful support from the suppliers of ADSL Routers in this class. This section of the download center is broken down by SBC Edge release and includes the following content:.
To access the software files, logon to using a valid account. To download the software, see the following procedure:. In this section:. Enter your Ribbon-provided credentials to log on to the portal. To determine the latest Software Bundle and the respective files, refer to the product Release Notes, and then perform the following:. Select the product's operating system from the Operating System drop-down list.
Click Request Download on the appropriate software bundle. This opens the Software Download Form. Co mplete th e Software Download Form.
Customer Support emails you when the bundle is ready to download. Click on the link in the email and then follow these steps:. Click the appropriate Software Request ID. The S-WebConnect will serialize the web requests and therefore avoid two parallel connections. Example For this example the following configuration is to be done in the MB panel configuration:.
If a webconnection is established over modem with the current Webconnect 2. Problem If all files except the. It is always necessary to execute a reload. Solution To solve this problem the htm or html file has to be downloaded to the PCD using the Webbuilder.
The SBC. However, in some cases the SComm driver is required. How to find out whether WebConnect knows about the SComm driver? If you can not select e. The SComm driver is required if one of the following questions has to be answered with "Yes":. Where does WebConnect look for the SComm driver? WebConnect 2. For checking whether these entries exist, open the Windows Registry Editor by selecting "Run What to do if I don't have a SCommDll?
In case on your PC there is no Scomm installed which is the case with a stand-alone installation of WebConnect 2. Please first uninstall the previous version and then install the last version. In some special cases e. Where to find the WebConnect settings? Net WebConnect 2. This can be. Otherwise, just use the common way by. When using the SBC. Symptom When the SBC. Net WebConnect version 2. To return to windows As soon as any button on this Window is clicked, WebConnect and the system is shutting down as expected.
Reason The reason for this behaviour is that the WebConnect software in detail it is the "system tray icon" task does not get the information from the Windows OS that the system is shutting down until the user has clicked a button on the window mentioned.
This information that the system is shutting down is only sent from Windows to the SBC. Net WebConnect after the user has klicked a button on the window. As result, WebConnect does not shut down until a button on the window is clicked. Solution In order to avoid this behaviour, it is possible to disable the "system tray icon task".
If this task is not running, it does not need to be stopped and the problem is avoided. On the other hand, there is no indication in the system tray that WebConnect is running. In order to disable the "system tray icon", proceed as following:. Remark If the system tray icon is not shown, it is not possible to call the WebConnect configuration page directly from the context menu of the icon. My start-page i. But my start-page's not displayed. The default Firmware page or the error message 'start.
Symptom SBC. The start-page e. But when typing the URL in the browser, the start-page is not displayed. Instead, the default firmware page on a PC or the error message 'start. Reason The reason for this behaviour is that the browser requests the start. The PCD itself already has the default firmware page, because there is no "user specified" start.
Solution The solution is:. General introduction For connecting a PCD to the internet using an ADSL router, the principal understanding of the functionality and tasks of a router need to be understood.
In a second step, the communication protocol for the connection is to be defined because every of the following protocols does require other configurations of the router. The attached document tries to explain the router functionality and tries to point out relevant information for connecting a PCD to the Internet and realizing the communication over the following protocols:.
For each of these protocols, please refer to the corresponding chapter in the attached document. Important remark concerning security Please consider the fact that the connectivity of a PCD on the internet does also mean that everyone can connect to the system. Therefore the interfaces over which the PCD can be reached from the internet need to be protected additionally if the web server can be reached from the internet and no security is implemented, everyone can e.
We therefore recommend whenever possible to use a VPN connection rather than just forwardig ports. If this is not possible:. This means that simuntaneously 12 Web browsers can communicate with the S-Web server. The connection of a 13th browser would be disconnected directly.
This number can be extended to 24 listener sockets in the Device Configurator from PG5 2. This means that there's still an upper limit. There's a way to define this 'unlimited' number of connection. You can define all the possible connections to the PCD, i. In this way, all the different Browsers requests and connections are tunneled through the S-Web Connect.
There's only one point you have to pay attention: Per default, the S-Web Connect limits to define a maximum of 15 connections. But you can adjust this limit in the 'Saia. T using WebConnect 2. T RIO, it is possible identifying e. After clicking the button "Download", the button "Start Monitoring" remains inactive.
Reason The reason for this behaviour is that WebConnect 2. The refreshing method in the Web connect settings, section "setting webconnect" is set default to "Cache fill once". If during the installation of PG5 1. Net Web-Connect there is an Error message: "Error Symptom During the installation of PG5 1.
Net Web-Connect on general there is following Error message: Error Net Web-Connect from a external server. Net Web-Connect from an external server. Solution 1 To solve the problem, copy the setup file of SBC. Net Web-Connect locally on your PC. Possible reason 2 You try to install PG5 1.
In details to change the installation folder of PG5 1. Problem When accessing several CPU's with the same Webconnect it would be comfortable to create subfolders. For each station you can create a subfolder with the name of the connection for this station e.
In these subfolders you can place all files which are only for this station. There you have the possibility to adapt different modem parameters like baud rate, data protocol and so on.
Yes, this is possible in WebConnect 2. Unforunately, the indication in the WebConnect configuration page is somehow missleading because it is written IP address, and no indication of an URL is given. Reason The stations are only saved after a timeout of 2 minutes ms or if SWebConnect is closed before shuting down the panel. Solution Close SWebConnect before shutting down the panel or make the timeout shorter p. This can be done in the SWebconnect.
The S-WebConnect 2. Net Framework 2. If the. Net Framework is not installed the S-WebConnect 2. Symptom When trying to lauch the S-WebConnect 2.
Instead an window with the content "SWebConnect. Click on OK to terminate the application" appears. Reason The S-WebConnect 2. In case the framework is not installed, the S-WebConnect fails to start. Solution Install the Microsoft. The installer for the.
0コメント